Diagnostic Equipments

  • BLOOD GAS & CHEMISTRY ANALYZER

    271,186.44

    Blood Gas & Chemistry Analyzer – Features

    Rapid

    • Fully Automated – Auto Sampling

    • Test Time – Less than 1 minute

    • Built in printer for results

    Reliable

    • Principle: Innovative microfluidic and micro sensor technology

    • Parameters Measured: pH, pO2, pCO2, Na, K, Ca, Cl, Glu, Lac, Hct

    • Sample types: Arterial, Venous, Capillary, Mixed, CPB, Aqueous

    • Triple Result Guarantee: Ensured with Calibrator, Control and Electronic simulator

    • 12 Months Cartridge Shelf life

    Convenient

    • Micro sample – 140 µl

    • Zero maintenance

  • ECG 12 Channel

    80,508.47

    ECG1200G is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart and histogram of P-R interval, case database management.

    Function
    1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
    2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
    3)Multiply printing modes and formats, including auto 12×1, auto 6×2+1, auto 6×2+1_H, auto 6×2, auto 6x2_H, auto 3×4+1, auto 3×4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
    4)Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
    5)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
    6)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
    7)In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.

  • ECG 3 Channel

    29,661.02

    ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management.

    Function

    1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
    2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
    3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
    4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
    5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.

  • ECG 6 Channel

    50,847.46

    ECG600G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management.

    Function
    1)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
    2)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
    3)Full-digital filter design, anti-baseline drift, AC and EMG interference.
    4)Adjust the baseline automatically, optimize the print setting and optional rhythm leads.
    5)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
    6)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
    7)With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency.
    8)Sync collection for 12-lead ECG, multiply printing formats, including 2×6+1(rhythm lead), 2×6, 3×4, 3×4+1(rhythm lead), 4×3, 4×3+1(rhythm lead), 6×2, 6×2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc.
    9)Display of 3/6/12-lead ECG, “Lead off” and “Lack of paper” on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database.
    10)Time print can be set to every 1/2/3/5/10/20/30/60 minutes.
    11)Print setting, including “Print and save”(print waveform and save case), “Print no save”(only print waveform but not save case), “Save no print”(only save case but not print waveform).
    12)AC/DC, built-in rechargeable lithium battery and auto-protection circuit, and automatic power off when there is no operation in appointed time.
    13)Store more than 1000 cases, convenient for case review and statistic.

  • Fully Auto Hematology Analyzer – Quickcell Plus Neo

    237,288.14
    • Throughput : 60 samples/hour
    • Principle: Impedance for WBC, RBC, PLT Cyanide-free method for HGB
    • Parameters: 22 parameters including WBC, Neu#, Lym#, Mid#, Neu%, Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW-CV, PDW-SD, PCT, P-LCR and P-LCC Histograms 3 histograms (WBC, RBC, PLT) & Alarm for abnormal results
    • Reagent: Diluent: 20L, Lyse: 500ml & Probe cleanser: 50ml
    • Print: Auto-print, Manual print
    • Communication: Support Bi-directional LIS
    • Language: English, Spanish, Italian, French, Russian, etc.
    • Input and output: 10-inch touchscreen
    • Internal printer, support external printer
    • Interface: USB port, Network port
    • Storage: 50000 Results with Histograms
    • Blockage clear: High voltage, high-pressure flush
  • Genvet VH30 3 Part Automated Hematology Analyzer

    296,610.17

    Assays: 24 parameters(including WBC, Neu#, Lym#, Gran#, Neu%, Lym%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW-SD, PDW-CV, PCT, P-LCR, P-LCC, NLR, PLR)

    18+ Species
    Cat, Dog, Rabbit, Sheep, Goat, Cattle, Horse, Rat, Mouse, Llama, Deer, Musk deer, Monkey, Tiger, Dolphin, Pig, Camel, Ferret.

    Reagents
    2 Reagent (1 Lyse + 1 Diluent)
    1 Probe cleanser for maintenance

  • Glucometer – Glucospark

    357.14
    Glucose Ranges 20 – 800 mg/dL
    Fill Direction Automatic
    Sample Mode Capillary
    Sample Whole Blood
    Sample Volume 0.5 µL
    Analysis Time 5 Seconds
    Battery 3v Lithium Battery (CR2032) Lasts for 1000 tests
    Relative Humidity 10-95% (Non-Condensing)
    Operating Temperature 2-50 Degree Centigrade
    Strips Storage Temperature 0-50 Degree Centigrade
    Interference Minimal
    Memory 1000 Readings
    Shelf Life of Strips 24 months (From Date of Manufacturing)
    Display 48 mm (diagonally) LCD
  • Glucometer – Glucospark with 25 Strip

    535.71

    Glucometer + 25 Test Stip + 25 Lancet + Lancet Device

    Glucose Ranges 20 – 800 mg/dL
    Fill Direction Automatic
    Sample Mode Capillary
    Sample Whole Blood
    Sample Volume 0.5 µL
    Analysis Time 5 Seconds
    Battery 3v Lithium Battery (CR2032) Lasts for 1000 tests
    Relative Humidity 10-95% (Non-Condensing)
    Operating Temperature 2-50 Degree Centigrade
    Strips Storage Temperature 0-50 Degree Centigrade
    Interference Minimal
    Memory 1000 Readings
    Shelf Life of Strips 24 months (From Date of Manufacturing)
    Display 48 mm (diagonally) LCD
  • Glucometer Glucospark + 50 Strips & Lancet Combo

    762.71
    Glucose Ranges 20 – 800 mg/dL
    Fill Direction Automatic
    Sample Mode Capillary
    Sample Whole Blood
    Sample Volume 0.5 µL
    Analysis Time 5 Seconds
    Battery 3v Lithium Battery (CR2032) Lasts for 1000 tests
    Relative Humidity 10-95% (Non-Condensing)
    Operating Temperature 2-50 Degree Centigrade
    Strips Storage Temperature 0-50 Degree Centigrade
    Interference Minimal
    Memory 1000 Readings
    Shelf Life of Strips 24 months (From Date of Manufacturing)
    Display 48 mm (diagonally) LCD
  • HB Meter – Haemoglobin Test Meter

    3,728.81
    Designed for POC Testing
    • Portable handheld
    • Large, easy-to-read LCD
    • Stores up to 1,000 results

    Accurate

    • Precise results equivalent to laboratory analyzers
    • Wide Hb measurement range of 4.5 – 25.6 g/dL
    • Calculated Hct range of 13 – 75%

    Quick & Convenient

    • Results in < 15 seconds
    • Auto-calibration
    • Fast data transfer via Mini USB port
  • HB meter Test Strips – 50 Test Strip per Pack

    1,428.57
    Sample Type Blood
    Sample Volume 50 uL Whole Blood
    Accuracy 0.95
    Shelf Life 12 Months
    Packing Type Box
    No Of Strips 50 Strips
  • Hemoglobin Meter + 50 HB Test Strips – Hemo Spark + Strip

    4,305.08

    Including 50 Test Strip in this Meter

    Methodology Reflectance Photometer
    Test Time Less than 30 seconds
    Automatic Shut Off 5 minutes after last use
    Meter Size 100 mm × 54.5 mm × 25.5 mm
    Display Size 38.5 mm × 37.5 mm
    Weight 72 g (without batteries)
    Meter Storage Conditions 0 – 50 ºC (32 – 122 ºF)
    Operating Conditions 2 – 40 ºC (35.6 – 104 ºF)
    Working Humidity 5 – 95% RH
    Analyzer Port USB Cable for Data Transfer & Power
    Capabilities USB Data Transfer to PC and Printer
    Meter Warranty 3 Years
    Strip (Working Environment) Working Temperature 2 – 40 ºC and Humidity 5 – 95%
    Strip (Storage Environment) Storage Temperature 2 – 40 ºC and Humidity 5 – 95%
    Strip Shelf Life 18 Months
    Auto Calibration Auto/Self Calibrations
    Sensitivity More than 80%
    Specificity More than 80%
    Bias (Limits of Agreement) 0.5 g/dL (±1gm/dL)
    Accuracy 98%
    Reproducibility CV : < 3%
    Measurement Range 0 – 25.6 g/dL, 0 – 256 g/L, 0 – 15.9 mmol/L
    Sample Whole blood (Capillary, Venous, Arterial)
    Sample Volume 10 µL
    Power Source 3 AAA Rechargeable Batteries (1.5V), AC Adapter (Mini USB, 5V DC, 1A)
    Battery Life 100 hours or 1000 tests
    Units of Measure g/dL, g/L, mmol/L
    Memory 1000 records with date and time