Scientific Equipment's

  • D-Dimer i chroma

    • Diagnosis diseasesDeep Vein Thrombosis, Pulmonary Embolism
    • Rule out suspected deep vein thrombosis (DVT) and pulmonary embolism
    • Differentiate acute pulmonary thromboembolism and non-ST segment elevation myocardial infarction (NSTEMI) patients by combining D-Dimer and Troponin I tests 8
    • D-Dimer based protocols have shown to be the most cost-effective to rule out suspected pulmonary embolism 9
  • Dissolved Oxygen Meter Microprocessor Based

    8,640.0011,040.00

    Features

    • Microprocessor Dissolved Oxygen Meter
    • KLDOM Series automatically detect the dissolved oxygen value of distilled water by detecting the temperature value of that
      solution.
    • 2 Point auto-calibration Blank Sodium Sulphate and standard distilled water.
    • Automatic Temperature Compensation ensures high accuracy of measurements.
    • Design & Specification are subject to change without any prior notice.

  • Double Beam UV-VIS Spectrometer

    208,000.00

    Basic Mode :

    To measure the Absorbance and Tranmittance

    Quantitative :

    1. Coefficient Method
      2. Standard Curve Up to 10 Standard sample may be used to establish a curve. Four methods for fitting a curve through the calibration points : Linear fit. Linear fit through zero, Square fit and cubic fit.

    Wavelength Scan :

    1. The wavelength scan intervals are 0.1,0.2,0.5,1,2 & 5 nm
      2. Fast, Medium and Slow scan speed are available. They vary from 100 to
      3600 nm/min
      3. Wavelength are scanned from high to low so that the instrument waits at high.
      Wavelength and it minimizes the degradation of UV sensitive samples.

    Design & Specification are subject to change without any prior notice.

  • Dry Bath Incubator Microprocessor Based

    6,900.00
    • Microprocessor based Dry bath Incubator
    • Dry bath Incubator is a temperature maintaining Device used to Incubate Blood samples before Testing.
    • KLDBI Series 24 Holes of 12.7mm are present in which user can incubate Blood Samples
    • Temperature Range of this instrument is Ambient to 70 C with 0.1 C Resolution and timing can be set from 0 to 99
      minutes.
    • PID Control, In – Built Times
  • pH Meter Microprocessore based

    5,840.008,320.00

    Salient Features

    • pH meter is most commonly used to determine the pH value of unknown solution.
    • KLPHM – 114 upto 3 point push button calibration with auto-buffer recognition.
    • KLPHM – 116 it is 5 point Push button Calibration with auto-buffer recognition.
    • Automatic Slope value calculations as all model is Microprocessor based.
    • Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range.
    • Expanded memory stores and reading to recall
    • Specification are subject to change without notice.

  • Photo Colorimeter Microprocessor Based

    6,300.00
    • Microprocessor based Photocolori meter
    • The series Advantage here of using LED based Filter instead of Glass Filters is the long life of Leds and also the selection Procedure
      of Wavelength are based on latest LED technology.
    • Built in 8 Digital Filters 30,000 Hours Life .
    • The instruments measures both Absorbance and % Transmittance
    • Wavelength Range 405 – 700 mm as it has a digital filters of wavelength 405, 450, 480, 520, 540, 578, 620 and 700 nm
  • Smart Heamoglobin Meter Microprocessor Based

    5,600.00

    Salient Features

    • Microprocessor Based Smart Hemoglobin Meter
    • The best recommended method is the Cyanmethemoglobin method. The advantage of being standardized and processing stable
      solution.
    • The instrument will Display Direct Hemoglobin Value All the Calculation can be done by the microprocessor.
    • The Advantage here of using LED Based filter instead of Glass Filters is the Long life of leds.

    Standard Accessories

    12.5 mm Round Test Tube – 5 Nos.
    Test Tube Holder – 1 No
    Operating Manual

    Design & Specification are subject to change without any prior notice.

  • TDS/EC METER MICROPROCESSOR BASED

    7,120.0010,400.00

    Features

    • Microprocessor Based TDS / EC Meter
    • Automatic Calibration the meter is capable for calibrating of 1 point with using standard solution.
    • Auto Ranging for TDS and EC
    • Automatic Temperature compensation Temperature value is displayed on the screen. The meter automatically compensates
      for optimum accuracy under variable temperature conditions.
    • Cell Constant : KLECM Series automatically adjust as per standard solution during calibration mode.
    • Specification are subject to change without notice.

  • Turbidity Meter Bench top Microprocessor Based

    7,900.00

    Features

    Microprocessor Based Turbidity Meter
    LCD Backlight Display 16X2 Alphanumeric
    2 Point calibration Distiller water & 200 NTU
    Soft Touch Keypad

    Standard Accessories

    Test Tube Set
    Operating Manual

    Specification are subject to change without notice.

  • UV-Visible Spectrometer

    100,800.00

    Salient Features

    • Microprocessor controlled, all parameters of this instrument can be easily set by numerical keys.
    • Unique optical system, 1200 lines/mm grating and imported receiver to ensure its sound performance .
    • The Instrument is supply with PC Software expands the capabilities of the instrument includes photometric analysis, Quantitative analysis, Spectra Scanning, Kinetics,
    • DNA/Protein analysis multi-wavelength test etc.,
    • Adopts 51 microcomputer system, and store 200 test data and 100 standard curves;
    • Equipped With USB port to connect with PC to Display Spectrum Scanning Kinetics and Multi Wavelength testing results on the screen.
    • Plug type deuterium lamp and tungsten lamp transfer tamps without optics debugging.
    • User Set Wavelength automatically through arrow keys to avoid operation errors.
  • Visible Spectrometer

    22,080.00

    Salient Features

    • Wavelength can set manually from the dial on the front panel
    • The Monochromator with a holographic flashing grating is used.
    • Digital display the measuring value
    • It has the advantage of high wavelength precision, good monochromaticity and low stray light.
    • A sample compartment is equipped with 50 mm cell holder
    • Direct concentration read – out
    • Concentration factor setting function.
    • RS232C Interface
x