ECG 3 Channel

Availability:

Out of stock


ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for โ€œLead offโ€ and โ€œLack of paperโ€, multi-language interface, AC/DC, selecting any rhythm lead, case database management.

Function

1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4ร—3, auto 3ร—4+1, auto 3ร—4, auto 2ร—6+1, auto 2ร—6, auto 3-2+1, auto 3-2, auto 1ร—12+1, auto 1ร—12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctorโ€™s burden.
5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.

35,000.00 40,000.00

Out of stock

ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for โ€œLead offโ€ and โ€œLack of paperโ€, multi-language interface, AC/DC, selecting any rhythm lead, case database management.

Function

1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4ร—3, auto 3ร—4+1, auto 3ร—4, auto 2ร—6+1, auto 2ร—6, auto 3-2+1, auto 3-2, auto 1ร—12+1, auto 1ร—12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctorโ€™s burden.
5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.

Performance

Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:โ‰ฅ 3.2s
Patient leak current: <10ยตA
Calibration voltage: 1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ยฑ5%, standard sensitivity: 10mm/mVยฑ2%
Noise level: <15ยตVp-p
Input circuit current: โ‰ค50nA
Input impedance: โ‰ฅ50Mฮฉ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
Manual record: set record according to record format, manually switching leads.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Paper size: 80mm(W)ร—20m(L)
Sampling frequency: 1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 25, 50mm/s, ยฑ5%
Rhythm: 25, 50mm/s, ยฑ5%
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ยฑ5%
Power supply:
AC: 100V~240V(50/60Hz)
DC: 7.4V/3500mAh rechargeable lithium battery
Fuse specification: two AC time lag fuse(ฯ†5ร—20mm), T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous working

Accessories

Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manualย ๏ผˆGB only๏ผ‰on request for other Language

Physical characteristic

Working environment
Temperature: 5โ„ƒ~40โ„ƒ
Relative humidity: 25%~95%(non-condensing)
Atmospheric pressure: 700hPa~1060hPa
Transport and storage environment
Temperature: -40โ„ƒ~+55โ„ƒ
Relative humidity: โ‰ค95%
Atmospheric pressure: 500hPa~1060hPa
Dimension: 315mm(L) ร— 215mm(W) ร— 77mm(H)
Weigh: 1.6Kg

EAN: 8900000124879 SKU: QLECG06 Categories: , ,