I Chroma 2 – Immunoassay Analyzer


Interface: Expansion of user interface through the adoption of Android OS

Display: 7 “touch panel provides operational stability and quick response

Portability: Battery for unexpected power failure or poor power environment for a certain period

Data storage and update: Available to store and search a large amounts of test results

Data backup and OS update using SD card

90,000.00 115,000.00

101,000.00 for 3 item(s)

ichroma™ II is an automatic or semiautomatic in-vitro diagnostic device that measures the concentration of analytes, contained in blood, urine, or other samples, in quantitative or semi-quantitative ways. Compared to the first- generation device, ichroma™, ichroma™ II has an improved user interface and display and an advanced optical system, which provide the user with disease test options in wide range

ADVANTAGE

Interface: Expansion of user interface through adoption of Android OS

Display: 7 “touch panel provides operational stability and quick response

Portability: Battery for unexpected power failure or poor power environment for a certain period

Data storage and update: Available to store and search large amount of test results

Data back-up and OS update using SD card

Optical technology: Improved fluorescence optical module for high sensitive diagnosis

Measurement modes: Single, multi-mode, QC test and review (save results) mode

Stability: Reduced risk of test error based on the equation saving function

Connectivity: Built-in printer, improved wired / wireless connectivity, LIS / HIS communication

USB hub chip supporting 4 USB ports

Convenience: Keyboard adaptable for non-touchpad user Improved convenience to input sample ID and tester ID

SPECIFICATIONS

Dimensions :   276 mm (L)x220 mm(W)x91 mm (H)

Power supply :   DC 12V/5A, AC/DC Adaptor, (AA battery) DC 1.5V X 4ea. Input 100-240V ~ 50/60Hz, 1.8A. Output :          DC 12V/5A

Data output :  7” touch color LCD

Motor Stepper Linear Actuator (5V, 0.34A)

Communication ports USB 4 ports, LAN port

Operation temperature/ humidity range15 ~ 35°C

Storage temperature/humidity range Temperature -20 ~ 50°C, Humidity Max. 70%

Data output LCD and built-in printer

Test result storage Patient test results (1,000) / System check results (500)

Standard material (control) test results (1,000)

I CHAMBER INCUBATOR

The i-chamber is an auxiliary device for the ichroma (ichroma™, ichroma™ II) systems and provides an environment set to the correct temperature to the ichroma cartridge when heating is required between tests. You can improve the reliability of your test results by keeping the temperature constant, one of the environmental factors that can cause unexpected errors in your test results.

 

TEST PARAMETERS

Weight 1.5 kg
Dimensions 27.6 × 22.0 × 9.0 cm
GTIN

CARDIAC

 

Test Parameter Sample Working Range Incubation

Time

Diseases
TnI Serum/Plasma 0.10-50 ng/ml 12 mins Myocardial Infarction
TnI Plus Whole blood/Serum/Plasma 0.01-15.00 ng/mL 12 mins Myocardial Infarction
CK-MB Whole blood/Serum/Plasma 3-100 ng/mL 12 mins Myocardial Infarction
D-Dimer Whole blood/Serum/Plasma 50-10000 ng/mL 12 mins Thrombosis
NT-proBNP Whole blood/Serum/Plasma 10-30000 pg/mL 12 mins Myocardial Infarction
Myoglobin Whole blood/Serum/Plasma 5-500 ng/mL 12 mins Myocardial Infarction
hsCRP Whole blood/Serum/Plasma 0.1-10 mg/L 3 mins Cardiovascular Inflammation
Triple Marker Whole blood/Serum/Plasma TnI: 0.01-15 ng/mL

CK-MB: 3-100 ng/mL

Myoglobin: 5-500 ng/mL

12 mins Myocardial Infarction

 

CANCER

 

Test Parameter Sample Working Range Incubation

Time

Diseases
PSA Whole blood/Serum/Plasma 0.1-100 ng/mL (for serum/ plasma)

0.5-100 ng/mL (for whole blood)

15 mins Prostrate Cancer
PSA Plus Whole blood/Serum/Plasma 0.07-50 ng/mL 12 mins Prostrate Cancer
AFP Whole blood/Serum/Plasma 5-350 ng/mL 15 mins Liver Cancer
AFP Plus Whole blood/Serum/Plasma 0.5-350 ng/mL 12 mins Liver Cancer
CEA Serum/Plasma 1-500 ng/mL 12 mins Cancers
CEA Plus Whole blood/Serum/Plasma 1-500 ng/mL 12 mins Cancers
iFOB Feces 25-1,000 ng/mL 10 mins Colorectal Cancer

 

DIABETES

 

Test Parameter Sample Working Range Incubation

Time

Diseases
HbA1c Whole Blood NGSP (%): 4-15% 12 mins Diabetes mellitus
Microalbumin Urine 2-300 mg/L 12 mins Diabetes mellitus
Cystatin C Serum/Plasma 0.1-7.5 mg/L 10 mins Renal disease

 

INFECTION

 

Test Parameter Sample Working Range Incubation

Time

Diseases
CRP Whole blood/Serum/Plasma 2.5-300 mg/L 3 mins Inflammation
PCT Whole blood/Serum/Plasma 0.1-100 ng/mL 12 mins Sepsis
PCT Plus Whole blood/Serum/Plasma 0.02-50 ng/mL 12 mins Sepsis
ASO Serum/Plasma 25-800 IU/mL 12 mins Rheumatic fever
HbsAg Whole blood/Serum/Plasma 0-300 COI 12 mins Hepatitis B
Anti-HBs Whole blood/Serum/Plasma 0-500 mIU/mL 15 mins Hepatitis B
Anti-HCV Whole blood/Serum/Plasma 0-300 COI 12 mins Hepatitis C
ROTA Feces 1.3 X TCID50/mL 12 mins Rotavirus infection
Rota/Adeno Feces Qualitative 12 mins Viral gastroenteritis
NORO Feces GI 0.04 – 0.2 ng/mL 12 mins Norovirus infection
Dengue NS1 Ag Whole blood/Serum/Plasma 1 x 102 pfu/mL 12 mins Dengue
Dengue IgG/IgM Whole blood/Serum/Plasma Qualitative 12 mins Dengue
Zika IgG/IgM Whole blood/Serum/Plasma Qualitative 12 mins Zika virus infection
HIV Ag/Ab Whole blood/Serum/Plasma P24: 2 IU/mL 15 mins HIV infection
Influenza A+B Nasopharyngeal swab/Nasal aspirate Qualitative 10 mins Influenza A and Influenza B
Strep A Nasopharyngeal swab/Nasal aspirate 4 x 103 cfu/test 5 mins Group A Streptococcal infection
Syphilis Whole blood/Serum/Plasma Qualitative 12 mins Syphilis

 

HORMONE

 

Test Parameter Sample Working Range Incubation

Time

Diseases
TSH Serum/Plasma 0.1-100 μIU/mL 12 mins Thyroid malfunction
TSH Plus Whole blood/Serum/Plasma 0.1-50 μIU/mL 12 mins Thyroid malfunction
T3 Serum/Plasma 0.5-5.0 ng/mL 16 mins Thyroid malfunction
T4 Serum/Plasma 10.23-300.0 nmol/L 16 mins Thyroid malfunction
Cortisol Whole blood/Serum/Plasma 80-800 nmol/L 10 mins Metabolism

 

FERTILITY

 

Test Parameter Sample Working Range Incubation

Time

Diseases
FSH Serum/Plasma 1-100 mIU/mL 15 mins Menopause/infertility
FSH Plus Whole blood/Serum/Plasma 0.1-110 mIU/mL 12 mins Menopause/infertility
Progesterone Serum/Plasma 4.45-127.2 nmol/L and 1.4-40 ng/mL 15 mins Fertility
HCG Serum/Plasma 2-3,000 mIU/mL 15 mins Pregnancy
B-HCG Whole blood/Serum/Plasma 5-50,000 mIU/mL 15 mins Fertility
B-HCG Plus Whole blood/Serum/Plasma 2-5,000 mIU/mL 15 mins Fertility
LH Serum/Plasma 1.0-100.0 mIU/mL 15 mins Ovulation
LH Plus Whole blood/Serum/Plasma 0.1-100.0 mIU/mL 12 mins Ovulation
PRL Serum/Plasma 1-100 ng/mL 10 mins Sexual disorder & infertility
PRL Plus Whole blood/Serum/Plasma 0.5 – 200 ng/mL 12 mins Sexual disorder & infertility
Testosterone Serum/Plasma 1-10 ng/mL 15 mins Sexual disorder

 

RHEUMATOID ARTHRITIS

 

Test Parameter Sample Working Range Incubation Time Diseases
RF IgM Whole blood/Serum/Plasma 8-200 IU/mL 5 mins Rheumatoid arthritis
Anti-CCP Whole blood/Serum/Plasma 5-200 U/mL 12 mins Rheumatoid arthritis

 

OTHERS

 

Test Parameter Sample Working Range Incubation Time Diseases
Ferritin Serum/Plasma 10-1000 ng/mL 10 mins Anemia
Ferritin Plus Whole blood/Serum/Plasma 1.5-1000 ng/mL 12 mins Anemia
Vitamin D Serum/Plasma 8-70 ng/mL 38 mins Bone disease

 

 

Reviews

There are no reviews yet

Be the first to review “I Chroma 2 – Immunoassay Analyzer”

Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

SHOPPING CART

close