[vc_row][vc_column]
- Blood Gas Analyzer's, POCT, Point of Care Devices, Point of Care Instruments
BLOOD GAS & CHEMISTRY ANALYZER
-9%
Blood Gas Analyzer's, POCT, Point of Care Devices, Point of Care InstrumentsBLOOD GAS & CHEMISTRY ANALYZER
Blood Gas & Chemistry Analyzer – Features
Rapid
Fully Automated – Auto Sampling
Test Time – Less than 1 minute
Built in printer for results
Reliable
Principle: Innovative microfluidic and micro sensor technology
Parameters Measured: pH, pO2, pCO2, Na, K, Ca, Cl, Glu, Lac, Hct
Sample types: Arterial, Venous, Capillary, Mixed, CPB, Aqueous
Triple Result Guarantee: Ensured with Calibrator, Control and Electronic simulator
12 Months Cartridge Shelf life
Convenient
Micro sample – 140 µl
Zero maintenance
SKU: BGEDN - Centrifuge
MicroSpin IMD 0806F
Product Features
- Capacity: 8 x 1.5/2ml;4 x PCR Strips
- Fixed RPM 6,000 rpm
- Extremely compact design dimensions: 190mm x 120mm x 120mm
- Quiet operation – < 50dB
- Compact design that can fit any workstation
- Rotor closing starts the run. Opening starts the run. No hassles
- Electric braking for quick stopping
SKU: IMD806F - Rapid Cards, Rapid Tests
One Step Chlamydia Trachomatis Antigen Detection Test
For in ~ vitro diagnostic use only
Store at 2 ~ 40 C
Kit Contents:
Each foil pouch contains:
1. Mytest Chlamydia Ag Device individually foil pouched with a desiccant.
2. Extraction Buffer.
3. Sample Applicator (Optional).
4. Package insert (instruction for use).SKU: MyCh25 - Biochemistry Reagents
CK MB Test Kit 2X25ML
PACK SIZE : 2 X 25ML
The CK-MB Liquid Reagent Test Kit is used for the quantitative determination of Creatine Kinase MB in human serum.
Ready-to-use, stable liquid reagent of 4:1 ratio
Detection range of 1.9 to 1000 U/L
Glucose (≤ 7 g/L), bilirubin (≤ 600 µmol/L), hemoglobin(≤ 1.25 g/L) and triglycerides (≤ 2.5 g/L) do not interfere
Factor or calibrator-based assay
SKU: ADX351 - Cardiac Profile, i Chroma Kits
i Chroma hsCRP – 25 Test Pack Kit
- Diagnosis diseases Acute coronary syndrome, Stroke. Peripheral artery disease, Myocadiac infarction
Sample Types
whole blood, plasma, serum
Reaction Time
3 mins
Detection Range
ichroma™ (0.1 – 10 mg/L)
Indication
Acute coronary syndrome, Stroke. Peripheral artery disease, Myocadiac infarction
SKU: ICHC25 - Biochemistry Reagents
Alpha Amylase Test Kit 2X10ML
- Pack Size: 2x10ml
Ready-to-use, single reagent
Linearity up to 2000 U/L
Bilirubin (mixed isomers) < 10 % interference up to 600 µmol/L, haemolysis < 10 % interference up to 5 g/L and lipemia < 10 % interference up to 5 g/L
Factor or calibrator-based assay
SKU: ADX261 - Critical Care Instruments, ECG Machine, Other Equipments
ECG 3 Channel
ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management.
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.SKU: QLECG06 - Rapid Cards, Tropical/ Parasitic
Malaria Pf/Pan Ag Rapid Test – 30 No’s/Pack
*It Is Only For Professionals And Not For any Individual Use. Misuse Of This Kit Can Give Wrong Results.
Each kit contains:
- Individually sealed foil pouches containing:
- One cassette device
- One desiccant
- 5 µL Blood transfer devices (sample loops, mini plastic droppers or capillary tubes)
- Blood Lysis buffer (10 mL/bottle)
- One package insert (instruction for use)
- Individually sealed foil pouches containing:
SKU: AR0113C - Meters, POCT, Point of Care Devices, Point of Care Instruments
Hemoglobin Test Strip – Hemo Spark
-48%
Meters, POCT, Point of Care Devices, Point of Care InstrumentsHemoglobin Test Strip – Hemo Spark
Strip (Working Environment) Working Temperature 2 – 40 ºC and Humidity 5 – 95% Strip (Storage Environment) Storage Temperature 2 – 40 ºC and Humidity 5 – 95% Strip Shelf Life 18 Months Auto Calibration Auto/Self Calibrations Sensitivity More than 80% Specificity More than 80% Bias (Limits of Agreement) 0.5 g/dL (±1gm/dL) Accuracy 98% Reproducibility CV : < 3% Measurement Range 0 – 25.6 g/dL, 0 – 256 g/L, 0 – 15.9 mmol/L Sample Whole blood (Capillary, Venous, Arterial) Sample Volume 10 µL SKU: HBSPARK02